| Traffic Control Inductive Loop Detector Presence signal / Pulse Signal CE / FCC
   
 
          
            | Model Number: | LD-202-12B | Place of Origin: | China |  
            | Brand Name: | Noble | Certification: | Patent,ISO9001-2008,CE,FCC |  
            | Minimum Order Quantity: | 5PCS | Price: | USD0-200/pc |  
            | Packaging Details: | cartons | Delivery Time: | 2-3days |  
            | Payment Terms: | Western Union, T/T | Supply Ability: | 20000pcs per months |  Detailed Product Description 
          
            | Loop Inductance: | 20-2000uh | Work Voltage: | 12VDC |  
            | Direction Detector: | CH1 To CH2,or Ch2 To Ch1 Direction Detection | Housing Color: 
 | White Or Black |  
            | Response Time: | 20MS | Operation Temp: | -40℃ To +70℃ |  
            | Weight: | 0.2KG | Sensitivity: | 8 Levels,(0 Is Lowest , 7 Is Highest) |  
            | Material: | ABS | Relay Signal: | Presence Signal Or Pulse Signal |    Traffic Control Inductive Loop Detector Presence signal / Pulse Signal CE / FCC Description: The LD-200 series detector may be configured for any one of the following modes: Presence Mode Pulse Mode AB Logic Presence Mode(Barrier Operation) AB Logic Pulse Mode(Counting Logic)   Loop detectors in recent years have become a popular tool having innumerable applications in policing, right from surveillance operations to traffic control.
 Automation of gates and doors has become a popular usage of the loop detector.
   The loop consists of several loops of wire and consideration should be giving to the loop sensitivity when installing on different surfaces. Setting the correct sensitivity allows the loop to operate with maximum
 detection (8 levels via a trimpot). When detection occurs, the detector
 energises 2 relays for the output (each can be configured individually).
 This energising of the relay can be configured into different modes,
 by selecting the respective dip switch.
   Fault Output:   Blinks slowly: It maybe because the loop is short circuit or the no:                        of turns is not enough.
 Blinks faster: It maybe because the loop is open or the no: of turns is too many.
 
 
          
            | Technical Parameter for single channel vehicle detector | Loop Inductance | 20-2000μH |  
            | Response Times | 10-90MS |  
            | Sensitivity | 8 levels,(0 is lowest, 7 is highest) |  
            | Visual Indications | Power LED-Red, Channel LED-Green |  
            | ABS | automatic sensitivity boost |  
            | Direction detection | CH1 and CH2 flow direction detection |  
            | Loop frequency | 4 setting(low,Med-low,Med-Hi,High) |  
            | Housing Material | ABS |  
            | Housing Color | Black,Or White |  
            | Weight | 0.2KG/pc |  
            | Label Language | English |  
            | Connections | 11pin male(JEDEC B11-88) |  
            | Storage Temperature |  -40 to 80 Celsius degree |  
            | Normal Working Temperature |  -40 to 70 Celsius degree |  Applications:             The LD-202 Enhanced dual channel detectors can be used in a variety of applications in the parking and door / gate environments:
 To arm card readers and ticket dispensers.
 As a barrier/gate/door closing detector.
 As a barrier/gate/door opening detector (Free exit).
 To generate pulses for counting vehicles.
 Troubleshooting: 
          
            | Symptoms | Solution |  
            | If the detector is not working | Press reset |  
            | If red led indicator is not fully lit | Check for power supply |  
            | If green led
 indicator:
 | Blinks slowly | It maybe because the loop is short circuit or the no: of turns is not enough. |  
            | Blinks faster | It maybe because the loop is open or the no: of turns is too many. |  
            | If no: of turns is not enough | Lower the frequency (if the frequency is still too high, you must add more turns). |  
            | If no: of turns is too many | Higher the frequency (if the frequency is still too low, you must remove some turns). |  LD-202 Connections: 
 Ordering Information: LD-200  single channel, boxed, 1 type 11pin connects 100-240VAC(EU standard) LD-202  single channel, boxed, 1 type 11pin connects 12-24VADC(EU standard) LD-205  single channel, boxed, 2 type 11pin connects 100-240VAC(USA standard) LD-206  single channel, boxed, 2 type 11pin connects 12-24VADC(USA standard) Vehicle loop detector photo: 
 Tag:Car parking dual channel traffic detection,dual channels vehicle  counting detection. Brochure>>
 
 Software Copyright>>
 
 Certification>>
 
 Compare Video(with Nortech,EMX,Procon,BEA,and China Red loop detector:
 https://www.youtube.com/watch?v=LZPIMrxCSbk
 https://www.youtube.com/watch?v=0LUQTfA62zs
 https://www.youtube.com/watch?v=D5KgiFt4Wtc
 https://www.youtube.com/watch?v=HRA0fgTvkc8
 https://www.youtube.com/watch?v=Fv1XkRFOSfw
 Tag :  traffic light detector, inductive loop traffic detector
 our other loop detector sale;Blinks Slowly Traffic Loop Detector -40 To 70 Celsius Degree For Parking Control
 LD - 205 Direction Traffic Loop Detector , Parking Magnetic Vehicle Detector
 LD - 200 Enhanced Double Loop Detector For Garage Door Opener
 ABS Housing Dual Loop Detector 4 Setting with Vehicle Counting
 Dual Channel Traffic Loop Detector With Analysis , Traffic Light Detector
   |